MMaterialNews vom 05.07.2012

Electronics: Northwestern Researchers Create “Rubber-Band Electronics”

For people with heart conditions and other ailments that require monitoring, life can be complicated by constant hospital visits and time-consuming tests. But what if much of the testing done at hospitals could be conducted in the patient’s home, office, or car?
Scientists foresee a time when medical monitoring devices are integrated seamlessly into the human body, able to track a patient’s vital signs and transmit them to his doctors. But one major obstacle continues to hinder technologies like these: electronics are too rigid.

Researchers at the McCormick School of Engineering, working with a team of scientists from the United States and abroad, have recently developed a design that allows electronics to bend and stretch to more than 200 percent their original size, four times greater than is possible with today’s technology. The key is a combination of a porous polymer and liquid metal.

A paper about the findings, “Three-dimensional Nanonetworks for Giant Stretchability in Dielectrics and Conductors,” was published June 26 in the journal Nature Communications.

“With current technology, electronics are able to stretch a small amount, but many potential applications require a device to stretch like a rubber band,” said Yonggang Huang, Joseph Cummings Professor of Civil and Environmental Engineering and Mechanical Engineering, who conducted the research with partners at the Korea Advanced Institute of Science and Technology (South Korea), Dalian University of Technology (China), and the University of Illinois at Urbana-Champaign. “With that level of stretchability we could see medical devices integrated into the human body.”

In the past five years, Huang and collaborators at the University of Illinois have developed electronics with about 50 percent stretchability, but this is not high enough for many applications.

One challenge facing these researchers has been overcoming a loss of conductivity in stretchable electronics. Circuits made from solid metals that are on the market today can survive a small amount of stretch, but their electrical conductivity plummets by 100 times when stretched. “This conductivity loss really defeats the point of stretchable electronics,” Huang said.

Huang’s team has found a way to overcome these challenges. First, they created a highly porous three-dimensional structure using a polymer material, poly(dimethylsiloxane) (PDMS), that can stretch to three times its original size. Then they placed a liquid metal (EGaIn) inside the pores, allowing electricity to flow consistently even when the material is excessively stretched.

The result is a material that is both highly stretchable and extremely conductive.

“By combining a liquid metal in a porous polymer, we achieved 200 percent stretchability in a material that does not suffer from stretch,” Huang said. “Once you achieve that technology, any electronic can behave like a rubber band.”

The graduate student Shuodao Wang at Northwestern University is a co-author of the paper.

Source: Northwestern University - 02.07.2012.

Recherchiert und dokumentiert von:

Dr.-Ing. Christoph Konetschny, Materialberater, Inhaber Materialsgate
Die Recherche und Aufbereitung der in diesem Dokument genannten Daten erfolgte mit größter Sorgfalt.
Für die Richtigkeit, Gültigkeit, Verfügbarkeit und Anwendbarkeit der genannten Daten übernehmen wir zu keinem Zeitpunkt die Haftung.
Bitte diskutieren Sie die Verwendung und Eignung für Ihren konkreten Anwendungsfall mit den Experten der genannten Institution.

Sie wünschen Material- und Technologierecherchen zu diesem Thema?

Materialsgate steht für hochwertige Werkstoffberatung und innovative Materialrecherchen.
Nutzen Sie unseren Beratungsservice

MMehr zu diesem Thema

When one tiny circuit within an integrated chip cracks or fails, the whole chip – or even the whole device – is a loss. But what if it could fix itself, and fix itself so fast that the user never knew there was a problem?
A team of University of Illinois engineers has developed a self-healing system that restores electrical conductivity to a cracked circuit in less time than it takes to blink. Led by aerospace engineering professor Scott White and materials science and engineering professor Nancy Sottos, the researchers published their results in the journal Advanced Materials. “It simplifies the system,” said chemistry professor Jeffrey Moore, a co-author of the paper. “Rather than having to build in redundancies... mehr
Individual molecules have been used to create electrical components like resistors, transistors and diodes, that mimic the properties of familiar semiconductors. But according to Nongjian (NJ) Tao, a researcher at the Biodesign Institute® at Arizona State University, unique properties inherent in single molecules may also allow clever designers to produce novel devices whose behavior falls outside the performance observed in conventional electronics.
In research appearing in today's issue of Nature Nanotechnology, Tao describes a method for mechanically controlling the geometry of a single molecule, situated in a junction between a pair of gold electrodes that form a simple circuit. The manipulations produced over tenfold increase in conductivity. The unusual, often non-intuitive characteristics of single molecules may eventually be introduced into a broad range of microelectronics, suitable for applications including biological and chemical... mehr
A nanoparticle-infused film brings innovative lighting and display technologies closer to reality.
A moisture-resistant coating that extends the lifetime and reliability of plastic electronic devices, such as organic solar cells or flexible displays, has garnered the intense interest of developers of next-generation lighting materials. By cranking out large sheets of polymers bearing electronic circuitry using roll-to-roll technology, electronics manufacturers can substantially reduce their capital and processing costs. The possibilities for low-cost flexible panel lighting inspiring, says Senthil... mehr
Researchers from North Carolina State University have developed a memory device that is soft and functions well in wet environments – opening the door to a new generation of biocompatible electronic devices.
“We’ve created a memory device with the physical properties of Jell-O,” says Dr. Michael Dickey, an assistant professor of chemical and biomolecular engineering at NC State and co-author of a paper describing the research. Conventional electronics are typically made of rigid, brittle materials and don’t function well in a wet environment. “Our memory device is soft and pliable, and functions extremely well in wet environments – similar to the human brain,” Dickey says. Prototypes... mehr
RSS
facebook
xing
twitter
linkedin

MaterialCards Weekly

Ihr persönlicher und kostenfreier Material-Reminder - wöchentlich per E-Mail

Service:
Material­cha­rak­teri­sierung und Werkstoffprüfung

Sie benötigen leistungsfähigste Methoden der Material­cha­rak­teri­sierung und Werk­stoff­prü­fung zur Optimierung Ihrer Produkte?
Medizintechnische Untersuchungen
Korrosionstests
Charakterisierung von Composites
Schadensanalyse von Bauteilen
Bruchmechanik
Barriere-Eigenschaften
Charakterisierung von Nanobeschichtungen
Metallographie
Thermographie
Schadensanalyse von Produkten
Gefüge-Analytik
Automotive Testing
Untersuchung von Diffusionsschichten
Charakterisierung von Fügetechnologien
Prüfung von Kunststoffen
Element-Mapping
Charakterisierung von Katalysatoren
Charakterisierung von Coatings
Keramographie
Prüfung von Werkstoffen der Elektrotechnik
Medizintechnische Untersuchungen
Korrosionstests
Charakterisierung von Composites
Schadensanalyse von Bauteilen
Bruchmechanik
Barriere-Eigenschaften
Charakterisierung von Nanobeschichtungen
Metallographie
Thermographie
Schadensanalyse von Produkten
Gefüge-Analytik
Automotive Testing
Untersuchung von Diffusionsschichten
Charakterisierung von Fügetechnologien
Prüfung von Kunststoffen
Element-Mapping
Charakterisierung von Katalysatoren
Charakterisierung von Coatings
Keramographie
Prüfung von Werkstoffen der Elektrotechnik
Kontaktieren Sie uns – Wir leiten Ihre Fragestellung an einen unserer Kooperationspartner weiter, die alle anerkannte und zertifizierte Prüf­la­bore mit modernster Ausstattung be­treiben.

Empfohlene Literatur

Tibor Grasser et al.
Springer, Berlin